{"created":"2023-07-27T04:45:04.317282+00:00","id":45111,"links":{},"metadata":{"_buckets":{"deposit":"bb19b7b0-9324-4128-bc54-2120dfbf2ed6"},"_deposit":{"created_by":3,"id":"45111","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"45111"},"status":"published"},"_oai":{"id":"oai:tohoku.repo.nii.ac.jp:00045111","sets":["76:267"]},"author_link":["105857","105856","105855"],"item_4_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1953","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"334","bibliographicPageStart":"329","bibliographicVolumeNumber":"5","bibliographic_titles":[{"bibliographic_title":"Science reports of the Research Institutes, Tohoku University. Ser. A, Physics, chemistry and metallurgy"}]}]},"item_4_date_62":{"attribute_name":"登録日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-05-02","subitem_date_issued_type":"Created"}]},"item_4_date_63":{"attribute_name":"公開日(投稿完了日)","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-05-02","subitem_date_issued_type":"Created"}]},"item_4_date_65":{"attribute_name":"発行日","attribute_value_mlt":[{"subitem_date_issued_datetime":"1953","subitem_date_issued_type":"Created"}]},"item_4_date_80":{"attribute_name":"更新日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2010-01-27","subitem_date_issued_type":"Created"}]},"item_4_description_15":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_4_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"According as the two coils used in the magnetometer method are in the same axis or in parallel, two equations showing the relations of the equivalent distance between two poles to the distance between the magnetometer and the magnetized bar were deduced, and using the values of free magnetism in a soft iron bar determined by T. Yoshida and H. Kadooka, the positions of the equivalent poles were calculated. It was found that the positions of the equivalent poles were remarkably influenced by the distance between the magnetometer and the magnetized bar, and by the intensity of external field.","subitem_description_type":"Abstract"}]},"item_4_description_41":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"紀要類(bulletin)","subitem_description_type":"Other"}]},"item_4_description_66":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"356285 bytes","subitem_description_type":"Other"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.50974/00041674","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_34":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Tohoku University"}]},"item_4_radio_69":{"attribute_name":"公開範囲","attribute_value_mlt":[{"subitem_radio_item":"学外"}]},"item_4_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00408808","subitem_source_identifier_type":"ISSN"}]},"item_4_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00836167","subitem_source_identifier_type":"NCID"}]},"item_4_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"MASUMOTO, Hakaru"}],"nameIdentifiers":[{"nameIdentifier":"105855","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"OTOMO, Goro"}],"nameIdentifiers":[{"nameIdentifier":"105856","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"SUGIHARA, Makoto"}],"nameIdentifiers":[{"nameIdentifier":"105857","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-02-16"}],"displaytype":"detail","filename":"KJ00004195891.pdf","filesize":[{"value":"356.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00004195891.pdf","url":"https://tohoku.repo.nii.ac.jp/record/45111/files/KJ00004195891.pdf"},"version_id":"0abfebf2-d097-4a37-9fb4-34293b033336"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"On the Positions of the Equivalent Poles in a Magnetized Bar Tested by the Magnetometer Method","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"On the Positions of the Equivalent Poles in a Magnetized Bar Tested by the Magnetometer Method"}]},"item_type_id":"4","owner":"3","path":["267"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-05-02"},"publish_date":"2008-05-02","publish_status":"0","recid":"45111","relation_version_is_last":true,"title":["On the Positions of the Equivalent Poles in a Magnetized Bar Tested by the Magnetometer Method"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T12:55:48.135605+00:00"}